Resultado da pesquisa (2)

Termo utilizado na pesquisa strain rate

#1 - Evaluation of left atrial function in asymptomatic dogs with chronic myxomatous mitral valve disease: twodimensional feature-tracking echocardiography and Simpson’s monoplanar methods

Abstract in English:

The present study evaluated the volume and function of the left atrium by two-dimensional echocardiographic feature-tracking imaging (2D-FTI) and Simpson’s monoplanar modeling in dogs with asymptomatic degenerative mitral valve disease (DMVD). The study consisted of 80 dogs that were divided into the following three groups: Group 1, 21 dogs (A); Group 2, 30 dogs (B1) and Group 3, 29 dogs (B2). The variable strain (contraction phase) was significantly lower in Group 3 than in Group 1 (12.92±4.54 x 16.69±5.74, p=0.014), and significant differences in the contraction strain index (CSI) were observed between all of the groups that were evaluated (1 = 46.82±8.10, 2 = 39.88±8.03, 3 = 35.25±5.64, p<0.0001). The atrial diastolic volume index (AdVi) that was measured by 2D-FTI was significantly higher in Group 3 than in Group 1 (1.31±0.95 x 0.96±0.31, p=0.038), and the atrial cardiac index (ACI) was also higher in Group 3 than in Group 1 (102.38±80.18 x 78.19±33.38, p=0.030). Atrial function was assessed by Simpson’s monoplanar method, which demonstrated an increase in the left atrial systolic volume, while the contractile function decreased with an increasing disease severity (Group 1 0.21±0.06; Group 2 0.25±0.06; Group 3 0.32±0.08, p<0.0001). The intraobserver and interobserver assessments showed low to moderate variability; most of the values for the coefficient of variation for the variables that were analysed with each method were below 25%. Thus, DMVD was determined to cause an alteration in atrial function, especially in the contraction phase, and even in asymptomatic animals, and the methods of 2D-FTI echocardiography and Simpson’s monoplanar evaluation are sensitive and early methods for the detection of left atrial dysfunction.

Abstract in Portuguese:

O presente estudo avaliou o volume e a função atrial esquerda obtidos por meio da ecocardiografia bidimensional feature tracking (2D-FTI) e pelo método monoplanar de Simpson em cães saudáveis e cães com DMVD assintomáticos. Foram avaliados 80 cães distribuídos em três grupos: Grupo 1, 21 cães (classe A); Grupo 2, 30 cães (classe B1) e Grupo 3, 29 cães (classe B2). A variável strain (fase de contração) foi significativamente menor no Grupo 3 que no Grupo 1 (12,92±4,54 x 16,69±5,74, p=0,014) e para a variável índice de strain de contração (CSI), houve diferença estatística entre todos os grupos avaliados (1 = 46,82±8,10; 2 = 39,88±8,03; 3 = 35,25±5,64, p<0,0001). O índice de volume diastólico atrial (iVdA) mensurado por meio do 2D-FTI foi significativamente maior no Grupo 3 que no Grupo 1 (1,31±0,95 x 0,96±0,31, p=0,038), assim como para o índice cardíaco atrial (iCA) também foi maior no Grupo 3 (102,38±80,18 x 78,19±33,38, p=0,030). A função atrial avaliada pelo método monoplanar de Simpson demonstrou um aumento do volume atrial esquerdo e do volume sistólico do átrio esquerdo, enquanto que a função contrátil diminuiu com o aumento da gravidade da doença (Grupo 1 0,21±0,06; Grupo 2 0,25±0,06; Grupo 3 0,32±0,08; p<0,0001). A avaliação intraobservador e interobservador, demonstrou variabilidade baixa a moderada, uma vez que a maioria dos valores de coeficiente de variação se concentraram abaixo de 25% para as variáveis analisadas em ambos os métodos. Dessa forma, conclui-se que a DMVD causa alteração na função atrial, principalmente na fase de contração, mesmo em animais assintomáticos e que a ecocardiografia 2D-FTI e o método monoplanar de Simpson são métodos sensíveis e precoces na detecção da disfunção atrial esquerda.


#2 - Strain and strain rate by two- dimensional speckle tracking echocardiography in a maned wolf, 32(12):1336-1340

Abstract in English:

ABSTRACT.- Mantovani M.M., Silva A.C., Muzzi R.A.L., Oberlender G., Resende R.M., Muzzi L.A.L., Lacreta Junior A.C.C. & Nogueira R.B. 2012. Strain and strain rate by two- dimensional speckle tracking echocardiography in a maned wolf. Pesquisa Veterinária Brasileira 32(12):1336-1340. Setor de Clínica Médica de Pequenos Animais, Serviço de Cardiologia Veterinária, Departamento de Medicina Veterinária, Universidade Federal de Lavras, Campus Universitário s/n, Caixa Postal 3037, Lavras, MG 37200-000, Brazil. E-mail: adrianagudi@gmail.com The measurement of cardiovascular features of wild animals is important, as is the measurement in pets, for the assessment of myocardial function and the early detection of cardiac abnormalities, which could progress to heart failure. Speckle tracking echocardiography (2D STE) is a new tool that has been used in veterinary medicine, which demonstrates several advantages, such as angle independence and the possibility to provide the early diagnosis of myocardial alterations. The aim of this study was to evaluate the left myocardial function in a maned wolf by 2D STE. Thus, the longitudinal, circumferential and radial strain and strain rate were obtained, as well as, the radial and longitudinal velocity and displacement values, from the right parasternal long axis four-chamber view, the left parasternal apical four chamber view and the parasternal short axis at the level of the papillary muscles. The results of the longitudinal variables were -13.52±7.88, -1.60±1.05, 4.34±2.52 and 3.86±3.04 for strain (%), strain rate (1/s), displacement (mm) and velocity (cm/s), respectively. In addition, the radial and circumferential Strain and Strain rate were 24.39±14.23, 1.86±0.95 and -13.69±6.53, -1.01±0.48, respectively. Thus, the present study provides the first data regarding the use of this tool in maned wolves, allowing a more complete quanti&#64257;cation of myocardial function in this species.

Abstract in Portuguese:

RESUMO.- Mantovani M.M., Silva A.C., Muzzi R.A.L., Oberlender G., Resende R.M., Muzzi L.A.L., Lacreta Junior A.C.C. & Nogueira R.B. 2012. Strain and strain rate by two- dimensional speckle tracking echocardiography in a maned wolf. Pesquisa Veterinária Brasileira 32(12):1336-1340. Setor de Clínica Médica de Pequenos Animais, Serviço de Cardiologia Veterinária, Departamento de Medicina Veterinária, Universidade Federal de Lavras, Campus Universitário s/n, Caixa Postal 3037, Lavras, MG 37200-000, Brazil. E-mail: adrianagudi@gmail.com A obtenção de parâmetros cardiovasculares em animais selvagens são importantes de serem avaliados, assim como em animais de companhia, para a obtenção da função miocárdica e determinação precoce de alterações cardíacas que poderiam evoluir para insuficiência cardíaca . A ecocardiografia speckle tracking (2D STE) é uma ferramenta nova que tem sido utilizada em medicina veterinária, a qual tem demonstrado várias vantagens quanto ao seu uso, como a independência do ângulo de insonação e a possibilidade de se obter o diagnóstico precoce de alterações miocárdicas. Objetivou-se avaliar a função miocárdica esquerda de um lobo guará por meio do uso da 2D STE. Desta forma, foram obtidas as variáveis Strain e Strain Rate longitudinais, circunferenciais e radiais, assim como a velocidade e o deslocamento longitudinais e radiais, utilizando os cortes eixo longo paraesternal direito quatro câmaras, paraesternal esquerdo apical quatro câmaras e eixo curto paraesternal direito no plano dos músculos papilares. Os resultados das variáveis longitudinais fora -13,52±7,88, -1,60±1,05, 4,34±2,52 e 3,86±3,04 para Strain (%), Strain rate (1/s), deslocamento (mm) e velocidade (cm/s), respectivamente. Quanto ao Strain e Strain rate radiais e circunferenciais foram obtidos 24,39±14,23, 1,86±0,95 e -13,69±6,53, -1,01±0,48. Portanto, o presente estudo fornece os primeiros dados a respeito do uso desta ferramenta em lobos guarás, permitindo uma quantificação da função miocárdica de forma mais completa nesta espécie.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV